Module design, colorful touch screen controlled designPlug and play detectorShockproof shell designStandard deviation <5%, precision: 5%RSD ( relative standarddeviation)6-7 pieces of plug and play detectors optional,each same or different detector can be composed both independentlyor combined installation is available, can be equipped with any twosame or different plug and play detectors, realize efficientcomplementation.Temperature of furnace reaches to 325℃Equipped with gas sample automatic collector,liquid and solid head space sample heater, transportable gascylindersSensitivities: benzene: ≤0.1ug/L (liquid)Work environmental temperature: -5~40℃, humidity:0-95%, non-condensingHeating gradient of the furnace: 80℃/min, themaximum heating ratio of the column temperature is 25℃/minControlling precision of the column temperaturereaches to 0.001℃Fast cooling of temperature column (325-50℃),≤4min,Furnace wind tunnel type of design, programmedcontrolled cooling, fast coolingWindows XP GC, which can run among theenterprises net compatible workRemote control the data of GC viaLAN/WAN/VPNFor VOC the retention time is <30 sec, for SVOCwhich is <50 sec.Sampler injection repeatability is <3%RSD peakarea, retention time error is <1%RSD
Data base of >44000 kinds of elements, of which the green ones>1000 kinds.
Electronic ModePlug and play controller, furnace anddetectorInput and GC storage by touch screenDisplaying all the actual and setting value of GCparameterClients` parameter setting has protectionfunction for permissionFurnace temperature controlled program hasmultiple kinds of gradient for selectionsCarrier gas controlled program has multiplegradesSwitch control of relay and solenoid valve oftime orderAll the parameters for detectable probedisplaying in single screenTwo electric pressure controllersAtmospheric pressure and temperaturecompensationEPC controlled resolution ratio reaches0.1KpaMicro processer controlDigital signal of the detector outputUniversal voltage input: 220VAC, filtering andchanging via linearSource: 336W(48VDC ×7AMPS)DC electrical source available Basic Features:Plug and play module designMultiple standards application specificprofilesCompact electronic furnace and shockproofdesignColorful touch screen controlled designContinuous operation by internal GCPatent digital signal processInternal diagnostic programElectric pressure controller precision:0.001KPafFurnace resists 325℃ environmentaltemperatureTemperature gradient of furnace is 80℃/min,heating speed reaches to 80℃/min in maximum, moment heating ratiocan reach 25℃/sec, temperature controlled precision is±0.001°CFast cooling (325 to 50℃). ≤4 min,Compact and light designWater resistant briefcase size (52×40×21cm)
Weight: about 10kgOne or two compact gas cylinder (purchaseindependently available) Detector:Accuracy: <10%, precision: 5% RSDBoth independent and combined installations areavailable0.1℃ resolution ratio, maximum temperature is300℃
Realize 24 digit output via USD portEPC pressure controlled precision: 0.1KPa Available Detector:FID-------flame ionization detector (100×10-9glimit)PID-------photo ionization detector (10×10-9glimit)TCD------thermal conductivity detector (1×10-6glimit)HID-------hydrogen ionization detector (100×10-9glimit)NPD------ nitrogen-phosphorus detector (20×10-9glimit)TID--------thermal detector (20×10-9glimit)ECD-------electron capture detector (0.1×10-9glimit) Furnace Module:Temperature resistant up to 325℃ columntemperatureTemperature gradient of the furnace 80℃/minFast cooling (325 to 50℃), ≤4 min,200W heating elementMultiple temperature gradient set, precision is0.1℃Appearance size: 12.5×10.5×12.5cmSingle electron sample valve is availableSource: car inventor (convertor equipped),external handled rechargeable battery Sample Injector:One or two optional installationShunt or nun-shunt calibration, gas sampleneedn`t heatCircular injection tube coolingMultiple gradient set, precision is 0.1KPaEquipped with two control solenoid Digital Communication:Two-way connection general data systemUSB digital signal output Network ConnectionGC of operating Windows XP works in enterprisenet compatible networkThe computer of ETX structure can be used in theGC control and data readApplying the web of Windows network protocol forweb connectionLAN/WAN/VPN remote controlled GC data read
Standard Chromatograph FINEGC-1200